Hemp insulation: which material suits your wall?

Start with the construction, then choose the insulation. Compare fibre products and possible applications, including moisture, fire performance and the complete wall assembly.

Original schematic illustration – not a complete layer sequence or construction specification.

Start here

Not all hemp insulation is the same

Flexible batts and stuffing fibre

Fibre products can fill suitable cavities. Batts are cut to fit; stuffing material is installed to product instructions. Density, gaps and the declared application matter.

Loose fill and blown insulation

Loose material is not automatically a blowing product. Mechanical installation requires a product, density, settlement performance and method approved for the particular cavity.

Boards and facade systems

An insulation board is not automatically a render carrier or part of an external thermal insulation composite system (ETICS). Exterior use, fixings, reinforcement and render must belong to the evidenced system.

Hemp-lime is a different material group

Hemp-lime combines shiv with mineral binder. Installation, construction moisture and material values cannot be transferred from flexible fibre batts.

Which wall are you insulating?

Wall cavity · structural timber frame · other functional layers require project design

Timber frame

Suitable fibre products may fill the cavities. Design junctions, airtightness, moisture control and external weather protection as a complete assembly.

Room side · proposed internal insulation · existing wall

Existing wall: inside

Investigate condition and moisture sources first. Internal insulation changes temperature and moisture behaviour; reveals, floor junctions and timber joist ends need coordinated details.

Existing wall · proposed external insulation · system-specific weather protection

Existing wall: outside

Check whether the facade may be altered and assess the substrate, fixings and edges. Use hemp products only within an evidenced exterior wall or facade system.

Beige: insulation · Brown: timber · Grey: existing fabric · Orange: position of the insulation being considered. Original schematic illustration – not a complete layer sequence or construction specification.

A short note on roofs and floors

Between rafters or joists, installation and junctions differ from those beneath a loaded floor. Check the declared application, loads, airtightness and settlement; suitability for a wall does not automatically cover a roof or floor.

Four checks for the complete assembly

Moisture

Resolve water sources first. Neither vapour permeability nor natural fibre content replaces a working moisture design.

Fire

A product’s reaction to fire and a wall’s fire resistance are different measures. Linings, junctions and installation form part of system assessment.

Sound

Sound absorption by insulation is not the sound insulation of a whole wall. Consider mass, decoupling, junctions and flanking transmission.

Life cycle impact

Compare EPDs using an appropriate function, quantity and system boundary. Include binders, additives, transport, service life and end of life; stored biogenic carbon alone is insufficient.

λ and U answer different questions

Thermal conductivity λ describes a material in W/(m·K). A U-value describes heat transfer through the complete building element in W/(m²·K). A low λ-value is therefore not a complete wall assessment.

Worked example – deliberately simplified

Assume a homogeneous insulation layer with d = 0.16 m and λ = 0.040 W/(m·K). Its thermal resistance is R = d / λ = 4.00 m²·K/W. If we assume, purely for illustration, R = 0.50 m²·K/W for all other layers and surface resistances combined, U = 1 / (4.00 + 0.50) ≈ 0.22 W/(m²·K).

The 0.50 is an assumption, not a property of a particular wall. Timber fractions, thermal bridges, gaps and fixings are not calculated here. The appropriate design conductivity and complete building element must be determined for the real project.

Product reference: page 4 of the THERMO HANF COMBI JUTE EPD states λD = 0.040 and a design value of 0.041 W/(m·K). This example uses the declared value for explanation, not as a design recommendation. These values do not apply to all hemp products. EPD · PDF

Checklist before selecting a product

  1. Record the building element, existing fabric, moisture exposure and purpose.
  2. Check product documents and the evidenced application.
  3. Draw the complete layers, junctions and airtightness strategy.
  4. Assess moisture, thermal, fire and acoustic performance together.
  5. Specify installation density, workmanship, fixings and quality checks.
  6. Assess environmental impact using an appropriate EPD and comparable function.

Frequently asked questions

Can any hemp fibre be blown in?

No. Loose material and a tested blowing product are not interchangeable. Use a product suitable for the process and building element.

Does hemp insulation always need the same vapour control layer?

No. Type and position depend on construction, climate and use; there is no single membrane recommendation for every assembly.

Is hemp insulation suitable for every old wall?

No. Existing fabric, driving rain, rising or other moisture and proposed junctions must be assessed first.

Are all products pure hemp fibre?

No. Composition and additives differ; consult the specific product declaration.